The Rammer R05P breaker is a cost-effective solution to your everyday breaking applications. The R05P’s simple impact unit design with the incorporation of a nitrogen piston accumulator and a second pressure dampening membrane type accumulator provides its users with an excellent power-to-weight ratio.

This 266kg breaker features a robust, silenced and vibration suppressed housing making it ideal for use in urban areas.

R05P is compatible with carriers ranging from 3.0 – 7.5 tonnes. The remote rockbreaker monitoring hardware RD3 is optional for Performance Line breakers.

Key Specifications

Product Weight

266 kg

Product Carrier Weight

3.0 – 7.5 t

Oil Flow Range

35 – 70 l/min

Features

  • Twin handed
  • Vibration and sound suppressed
  • Flange mounting
  • Fast-change tool system
  • RD3 (optional)
  • Original RAMMER tools
  • Piston type accumulator
  • Excellent power-to-weight ratio

Applications

  • Primary demolition
  • Secondary demolition
  • Recycling
  • Trenching
  • Landscaping
  • Hire Fleet

Compatible with Chisel Tool, Moil Point Tool, Performance Pyramid Tool.

Specifications

Weight

266 kg

Minimum working weight, flange mounted *1

325 kg

Oil flow range

35 - 70 l/min

Impact rate (frequency)

400 - 1050 bpm

Operating pressure

110 - 155 bar

Pressure relief setting *2

200 bar

Pressure relief max

220 bar

Back pressure max

15 bar

Input power
18 kW
Tool diameter
68 mm
Pressure line connection (IN)
BSPP-internal 3/4"
Return line connection (OUT)
BSPP-internal 3/4"
Pressure line size, min. inner diameter

15 mm

Return line size, min. inner diameter

15 mm

Optimum oil temperature
40 - 60°C
Allowed oil temperature range
-20 - 80°C
Optimum oil viscosity at operating temperature
30 - 60 cSt
Allowed viscosity range
20 - 1000 cSt
Skid steer, robot weight, range *3
3.0 - 5.2 t
Carrier weight, range *3
4.0 - 7.5 t
Noise level, measured (2000/14/EC)
118 dB(A)
Noise level, guaranteed (2000/14/EC)
122 dB(A)
  • *1   Includes average mounting bracket and standard wear parts
  • *2   Minimum setting = actually measured operating pressure + 50 bar or 725 psi
  • *3   Check carrier allowed attachment weight from carrier manufacturer. Check application requirements.